Clinical trial

Safety and Effectiveness of Orbera365™ Intragastric Balloon System

Recruiting now · Not applicable · 3 countries · Registry ID NCT07062094

Recruiting nowNot applicableObservational

What this study is about

This is a prospective, multi-center, standard of care registry offered to subjects in the EU only that have already agreed to receive the Orbera365™ Intragastric Balloon (IGB) System for weight loss. Subjects that agree to participate in the registry will have data reported associated with standard of care weight management visits during the time the device is implanted (in-dwell period), with an additional visit 30 days after the removal procedure.

A promising-looking record is not the same as confirmed eligibility. The study team must review the full criteria and current recruitment status.

Basic eligibility

Age18 Years to Not listed
SexAll
Healthy volunteersNot accepted
ConditionObesity

Full registry criteria

Inclusion Criteria: 1. Subject is ≥ 18 years of age 2. Subject meets the indicated population for the device according to the Instructions for Use (IFU) including obese patients with the BMI of 30-50 kg/m2 for weight loss and patients with BMI 40 kg/m2 and above or a BMI of 35 kg/m2 with comorbidities before obesity or another surgery, unless contraindicated. 3. Subject is able to read, understand, and sign a written Informed Consent Form to participate in the registry Exclusion Criteria: 1. Subject is planning on becoming pregnant during the one year following study device placement 2. Subject will complete follow-up visits at a location that the treating physician does not practice 3. Subjects who are unable or unwilling to take prescribed proton pump inhibitor medication for the duration of the device implant. 4. Current use or use within the three months before the baseline visit of over-the-counter or prescribed weight loss supplements/medications. 5. Subjects who have conditions that are contraindicated for Orbera365™ IGB System as per the IFU, including, but not limited to: * The presence of more than one IGB at the same time. * Any inflammatory disease of the gastrointestinal tract including esophagitis, gastric ulceration, duodenal ulceration, cancer or specific inflammation such as Crohn's disease * Potential upper gastrointestinal bleeding conditions * A large hiatal hernia of \> 5cm or a hernia ≤ 5 cm associated with severe or intractable gastro- esophageal reflux symptoms * A structural abnormality in the esophagus or pharynx such as a stricture or diverticulum that could impede passage of the delivery catheter and/or an endoscope * Achalasia, symptoms suggestive of delayed gastric emptying, or presence of any other severe motility disorder that that may pose a safety risk during placement or removal of the device. * Gastric Mass. * Severe coagulopathy. * Taking aspirin, anti-inflammatory agents, anticoagulants or other gastric irritants and not under medical supervision. * Prior surgery involving the esophagus, stomach, and duodenum or bariatric surgery

Treatments and study arms

Intragastric Balloon

Device

The Orbera365™ IGB System is to be used in conjunction with a long-term supervised diet and behavior modification program designed to increase the possibility of long-term weight loss maintenance. The IGB is placed in the stomach and filled with sterile saline, causing it to expand into a spherical shape. The filled IGB is designed to occupy space and move freely within the stomach, potentially altering appetite and satiety to achieve weight loss.

Primary outcomes

Rate of Subjects with Serious Adverse EventsUp to 12 months

The rate of subjects with serious adverse events of interest associated with the extended length of the study device in-dwell time (between 6 and 12 months) and requiringe hospitalization, endoscopic or surgical intervention, or are life-threatening. Adverse events of interest include gastric outlet obstruction, spontaneous deflation that leads to obstruction, hyperinflation, and removal complications related to airway obstruction or esophageal laceration / perforation associated with compromised balloon integrity.

Rate of Treatment CompletersUp to 12 months

The rate of Treatment Completers that achieve ≥10% percent Total Body Weight Loss (%TBWL) at time of study removal procedure. Treatment Completer is defined as maintaining device therapy for the prescribed maximum allowed in-dwell period (up to12 months) or successfully achieving weight loss goal (e.g., at least 5% TBWL) and an early device removal for a reason other than an adverse event.

Study locations

4 locations were listed when this page was built. The first 40 are shown.

OB Klinika🇨🇿 Prague, Czechia
Dana Charpentier, MDContact
Dana Charpentier, MDPrincipal Investigator
EndoBes - Centre Medico Teknon🇪🇸 Barcelona, Spain
Román Turró Arau, MDContact
Román Turró Arau, MDPrincipal Investigator
Dorsia Clinic, Madrid Spain🇪🇸 Madrid, Spain
Elena AlcobaContact
Andrés del Pozo García, MDPrincipal Investigator
UHCW NHS Trust🇬🇧 Coventry, West Midlands, United Kingdom
Prof. Vinod MenonContact
Vinod Menon, Prof.Principal Investigator